Why a Linux Ethernet port negotiated below its rated speed

On this page
  1. Identify the interface
  2. Change one component at a time
  3. Separate link and traffic
  4. Try it
  5. Sources

Check advertised and negotiated modes at both Ethernet ends before replacing the network card.

Linux hardware diagnostics decision guide
  1. AdapterRecord supported and advertised modes
  2. Link partnerCheck the exact switch port
  3. TestRe-read speed after one cable or port change

Identify the interface

Use ip link to find the correct Ethernet interface. Run ethtool for that interface and note the current speed, duplex and auto-negotiation values. Record supported and advertised modes separately when the driver exposes them.

Change one component at a time

Swap the cable for a known-good cable of the appropriate category, or move to a documented higher-speed switch port. Keep the PC and test tool fixed. Check whether the link negotiates differently after each change.

Separate link and traffic

Even at the expected negotiated speed, transfer throughput can be limited by workload and storage. Run a network-only test after the link speed is stable so you can compare the Ethernet path separately from disk transfers.

Try it

Sources

  1. ethtool upstream manual
  2. iproute2 ip-link manual